<?xml version="1.0" encoding="utf-8" standalone="yes"?>
<Forecourt xmlns="http://www.wayne.se/2006-03-13/ForecourtConfig.xsd">
  <!--The Fuel grades configured for the forecourt-->
  <!--There is three grades configured. Only grade 1,2,4 is used on this site.-->
  <FuelGrades>
    <FuelGrade Id="1">
      <MinPrice>0.10</MinPrice>
      <MaxPrice>9.99</MaxPrice>            
    </FuelGrade>
    <FuelGrade Id="2">
      <MinPrice>0.10</MinPrice>
      <MaxPrice>9.99</MaxPrice>
    </FuelGrade>
    <FuelGrade Id="4">
      <MinPrice>0.10</MinPrice>
      <MaxPrice>9.99</MaxPrice>
    </FuelGrade>
  </FuelGrades>
  <!--Release profiles -->
  <ReleaseProfiles>
    <ReleaseProfile Id="1">
      <Used>true</Used>
      <Description>A descriptive text</Description>
      <Limits>
        <Limit FuelGradeId="1">
          <Amount>200</Amount>
          <Volume>20</Volume>
          <Time>1000</Time>
        </Limit>
        <Limit FuelGradeId="2">
          <Amount>100</Amount>
          <Volume>10</Volume>
          <Time>1000</Time>
        </Limit>
      </Limits>
    </ReleaseProfile>
  </ReleaseProfiles>
  <!--Tanks-->
  <Tanks>
    <Tank Id="1">
      <Used>true</Used>
      <TankGroupId>1</TankGroupId>
      <FuelGradeId>1</FuelGradeId>
      <MaxCapacity>5000</MaxCapacity>
      <LowLevelAlarmLimit>1000</LowLevelAlarmLimit>
    </Tank>    
    <Tank Id="2">
      <Used>true</Used>
      <TankGroupId>2</TankGroupId>
      <FuelGradeId>2</FuelGradeId>
      <MaxCapacity>6000</MaxCapacity>
      <LowLevelAlarmLimit>1000</LowLevelAlarmLimit>
    </Tank>
  </Tanks>
  <!--Tank groups-->
  <TankGroups>
    <TankGroup Id="1">
      <Used>true</Used>
      <LinkedTanks>
        <TankId>1</TankId>        
      </LinkedTanks>      
    </TankGroup>    
    <TankGroup Id="2">
      <Used>true</Used>
      <LinkedTanks>
        <TankId>2</TankId>
      </LinkedTanks>
    </TankGroup>
  </TankGroups>
  <Pumps>
    <Pump Id="1">
      <Used>true</Used>
      <ComLinkId>1</ComLinkId>
      <PhysicalDeviceId>1</PhysicalDeviceId>
      <Nozzles>
        <Nozzle Id="1">
          <Used>true</Used>
          <FuelGradeId>1</FuelGradeId>
          <PrimaryTankId>1</PrimaryTankId>          
        </Nozzle>
        <Nozzle Id="2">
          <Used>true</Used>
          <FuelGradeId>2</FuelGradeId>
          <PrimaryTankId>2</PrimaryTankId>
        </Nozzle>
      </Nozzles>      
    </Pump>
  </Pumps>
  <!--Price Poles-->
  <PricePoles>
    <PricePole Id="1">
      <Used>true</Used>
      <PricePoleSegments>
        <PricePoleSegment Id="1">
          <Used>true</Used>
          <FuelGradeId>1</FuelGradeId>
          <PriceGroup>FullService</PriceGroup>
        </PricePoleSegment>
      </PricePoleSegments>
      <ComLinkId>4</ComLinkId>
      <PhysicalDeviceId>1</PhysicalDeviceId>
    </PricePole>
  </PricePoles>
  <!--Communication links-->
  <ComLinks>
    <ComLink Id="1">
      <LinkName>FL1-2</LinkName>
      <LinkProtocolType>Dart</LinkProtocolType>
      <PhysicalLinkType>1</PhysicalLinkType>
      <BaudRate>9600</BaudRate>
      <StopBits>1</StopBits>
      <Parity>none</Parity>
    </ComLink>
    <ComLink Id="4">
      <LinkName>D1</LinkName>
      <LinkProtocolType>Dart</LinkProtocolType>
      <PhysicalLinkType>1</PhysicalLinkType>
      <BaudRate>2400</BaudRate>
      <StopBits>1</StopBits>
      <Parity>even</Parity>
    </ComLink>
  </ComLinks>
</Forecourt>