123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124 |
- using System;
- using System.Collections.Generic;
- using System.Text;
- namespace Dfs.WayneChina.IMisPlus.Models
- {
- /// <summary>
- /// Settings/parameters of fuel tank of legacy iFuel system.
- /// </summary>
- public class Tank
- {
- /// <summary>
- /// Id of the tank, used by system.
- /// Sps Field: `TankID`, type: tinyint(1)
- /// </summary>
- public int Id { get; set; }
- /// <summary>
- /// Product code of the fuel in the tank.
- /// Sps Field: `FuelNo`, type: char(10).
- /// ** Normally this field is filled with an integer.
- /// </summary>
- public string ProductCode { get; set; }
- /// <summary>
- /// Height of liquid
- /// Sps Field: `Height`, type: int(2)
- /// </summary>
- public ushort Height { get; set; }
- /// <summary>
- /// Maximum height
- /// Sps Field: `MaxHeight`, type: int(2)
- /// </summary>
- public ushort MaxHeight { get; set; }
- /// <summary>
- /// Minium height
- /// Sps Field: `MinHeight`, type: int(2)
- /// </summary>
- public ushort MinHeight { get; set; }
- /// <summary>
- /// Maximum volume
- /// Sps Field: `MaxVolume`, type: int(2)
- /// </summary>
- public ushort MaxVolume { get; set; }
- /// <summary>
- /// Minimum volume
- /// Sps Field: `MinVolume`, type: int(2)
- /// </summary>
- public ushort MinVolume { get; set; }
- /// <summary>
- /// Maximum volume
- /// Sps Field: `MaxWaterHeight`, type: int(2)
- /// </summary>
- public ushort MaxWaterHeight { get; set; }
- /// <summary>
- /// Maximum temperature
- /// </summary>
- public ushort MaxTemp { get; set; }
- /// <summary>
- /// Id of the probe of the tank gauge.
- /// Sps Field: `ProbeID`, type: varchar(32)
- /// </summary>
- public string ProbeId { get; set; }
- /// <summary>
- /// Offset
- /// Sps Field: `OffSet`, type: int(11)
- /// </summary>
- public int Offset { get; set; }
- /// <summary>
- /// Liquid fuel offset
- /// Sps Field: `OilOffSet`, type: int(11)
- /// </summary>
- public long OilOffset { get; set; }
- /// <summary>
- /// Water offset
- /// Sps Field: `WaterOffSet`, type: int(11)
- /// </summary>
- public int WaterOffset { get; set; }
- /// <summary>
- /// Probe address
- /// Sps Field: `ProbeAddr`, type: varchar(32)
- /// </summary>
- public string ProbeAddress { get; set; }
- /// <summary>
- /// Sps Field: `FixDate`, type: date, format: `0000-00-00`
- /// </summary>
- public DateTime InstallDate { get; set; }
- /// <summary>
- /// Sps Field: `FactoryNo`, type: char(20)
- /// </summary>
-
- /// <summary>
- /// The date that the tank is shipped (or manufactured).
- /// Sps Field: `FactoryDate`, type: date, format: `0000-00-00`
- /// </summary>
- public DateTime DateOfManufacture { get; set; }
- /// <summary>
- /// The life span limit of the tank.
- /// Sps Field: `LimitDate`, type: int(2)
- /// </summary>
- public ushort Life { get; set; }
- /// <summary>
- /// Manufacture of the tank.
- /// Sps Field: `FactName`, type: varchar(20)
- /// </summary>
- public string Manufacturer { get; set; }
- }
- }
|